Request a Prompt Quote on Qbc Diagnostics Llc Part Number 4451-QBCII with the NSN 6630012346794

Part Number: 4451-QBCII
Alternate P/N: 4451QBCII
Manufacturer: Qbc Diagnostics Llc
NIIN: 012346794
Item Name : Analyzer Clinical C
CAGE Code: 4AZY5
FSG: 66 Instruments and Laboratory Equipment
Country: USA
NCB Code: 01

Those searching for high-caliber NSN parts, military and defense parts, aerospace parts, and in-demand components like part number 4451-QBCII with the NSN 6630012346794 can count on Aero Procurement Services to provide them with the products they need to carry out operations as usual. You have reached our NSN RFQ page where you may fill out the required fields to receive a customized quote on Analyzer Clinical C items produced by reputable manufacturers like Qbc Diagnostics Llc. All we ask is that you include relevant details on this form, including your budget parameters, desired quantities, and expected delivery dates. With this information, a skilled account manager will craft a solution tailored to your needs and restrictions alike within 15 minutes or less.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/customer-terms-and-conditions/ . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

At Aero Procurement Services, we prioritize connecting our customers with the highest caliber NSN products, including those with the CAGE Code 4AZY5 and belonging to the FSC 6630 Chemical Analysis Instruments. In order to guarantee the reliability of products like part number 4451-QBCII, we choose to source only from trusted global manufacturers that we have vetted and placed on our Approved Vendor List (AVL), like Qbc Diagnostics Llc. More than that, we subject countless components to rigorous quality assurance measures like document verification and visual inspection to guarantee their fit, form, and function prior to purchase. Commence procurement with a competitive quote for items like part number 4451-QBCII NSN 6630012346794 today and see how simple purchasing can be.

Characteristics Data of NSN 6630-01-234-6794, 6630012346794

MRCCriteriaCharacteristic
ELECVoltage In Volts120.0 AND 220.0
CXCYPart Name Assigned By Controlling AgencyANALYZER, CLINICAL CHEMISTRY
AKYDAccessory Components And QuantityELECTRO-OPTICAL MAGNIFICATION READER 1; WORK STATION 1; VENOUS-BLOOD PIPETTER 1
ACZBFrequency Rating50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
FEATSpecial FeaturesMICROPROCESSOR CONTROLLED ELECTRO-OPTICAL INSTRUMENT FOR MEASURING PACKED CELL VOLUMES AND CONVERTING TO RELATIVE VALUES;COMPONENTS INC.75X MONOCULAR MICROSCOPE,ROTATING TUBE CARTRIDGE ASSY;OPICAL ENCODER;UV ILLUMINATOR LAMP;VARIOUS LENSES AND FILTERS TO CAUSE STAINED WHITE CELLS AND PLATELETS TO FLUORESCE;12 PLACE HEMATOCRIT CENTRIFUGE WITH HEAD COVER,FIXED FIVE MINUTE TIMER;12,000 RPM SPEED CAPACITY;AND RCF OF 14,387 X G;TWO POSITION PIPETTER WITH FIXED VOLUME OF 111.1 MICROLITERS;WORK STATION WITH NUMBERED SLOTS FOR CAPILLARY TUBES;WELLS FOR WHOLE BLOOD TUBES AND RACK FOR STORAGE OF PIPETTER;OPERATION METHOD:ELECTRIC;EXTERIOR CONTAINER QUANTITY:1;THE NUMBER OF ALTERNATING CURRENT PHASE:TWO
SUPPSupplementary FeaturesCONT C/O TWO SEALED CALIBRATION CHECK TUBES; ONE VENOUS,ONE CAPILLARY; ONE PAIR FORCEPS; SPARE PIPETTER "O" RINGS AND GREASE,SPARE LAMPS FUSES,TWO THRUST PIVOTS,ONE 5/64 IN. HEX KEY AND TEST GUIDE; CAPABLE OF PERFORMING THE FOLLOWING QUANTITATIVE FUNCTIONS ON A CENTRIFUGAL BLOOD TUBE; HEMOGLOBIN,HEMATOCRIT,PLATELET COUNT,WHITE BLOOD COUNT,GRANULOCYTE COUNT,AND LYMPHOCYTE-MONOCYTE COUNT; FOR CAPILLARY MICROHEMATOCRIT TUBE KIT ORDER 6630-01-233-7594; FOR VENOUS MICROHEMATOCRIT TUBE KIT,ORDER 6630-01-233-7593 AND VENOUS HEMATOCRIT TUBE KIT 6630-01-233-9592; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED
MRCDecoded RequirementClear Text Reply
ALUEUniversal Medical Device Nomenclature System Code16298
ACDCCurrent TypeAC