Those searching for high-caliber NSN parts, military and defense parts, aerospace parts, and in-demand components like part number JB420P2 with the NSN 5950003013734 can count on Aero Procurement Services to provide them with the products they need to carry out operations as usual. You have reached our NSN RFQ page where you may fill out the required fields to receive a customized quote on Transformer Power items produced by reputable manufacturers like Amnetics Inc. All we ask is that you include relevant details on this form, including your budget parameters, desired quantities, and expected delivery dates. With this information, a skilled account manager will craft a solution tailored to your needs and restrictions alike within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
At Aero Procurement Services, we prioritize connecting our customers with the highest caliber NSN products, including those with the CAGE Code 11700 and belonging to the FSC 5950 Coils and Transformers. In order to guarantee the reliability of products like part number JB420P2, we choose to source only from trusted global manufacturers that we have vetted and placed on our Approved Vendor List (AVL), like Amnetics Inc. More than that, we subject countless components to rigorous quality assurance measures like document verification and visual inspection to guarantee their fit, form, and function prior to purchase. Commence procurement with a competitive quote for items like part number JB420P2 NSN 5950003013734 today and see how simple purchasing can be.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-301-3734 Item PartTypeName: TRANSFORMER,POWER | 5950 | 003013734 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
WE2189 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM SINGLE GROUP AND 0.148 INCHES MINIMUM SINGLE GROUP AND 0.165 INCHES MAXIMUM SINGLE GROUP0.165 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENTINTERNALLY SHIELDED SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.630 INCHES MAXIMUM3.630 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM1.630 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.1 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 184.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 184.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | 1PRIMARY,7 SECONDARY WINDINGS; ALL CURRENTS ARE SHOWN AS RECTIFIED; SECONDARIES 6 AND 7 ARE RATED THE SAME,0.1 AMP DC AT 16.5 AND 19.5 VOLTS RMS; 5TH SECONDARY IS 0.57 AMPS AT 21.50 AND 24.50 VOLTS RMS1PRIMARY,7 SECONDARY WINDINGS; ALL CURR |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB,SOLDER LUG |